The Polymer Society of Korea

Login Join
Login Join

SITE MAP

Program

Sessions

2L8 bookmark

고분자 합성: 정밀 제어 고분자 합성: 분자 수준에서 응용까지 (2)

  • Oct 01(Wed), 2025, 14:00 - 16:00
  • 8회장 (105호)
  • Chair : 고영운
14:50 - 15:15
bookmark

[2L8-7]

Organic X-Ray Image Sensors using a Medium Bandgap Polymer Donor with Low Dark Current

발표자하종운 (경상국립대학교)

연구책임자하종운 (경상국립대학교)

공동저자하종운 (경상국립대학교)

Abstract

The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations. However, this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors. This study presents a novel biTPD-based polymer donor (PBDT-biTPD) that exhibits excellent photodetection properties even in a thick photoactive layer, owing to the symmetric backbone and highly soluble molecular structure of biTPD. The ability of PBDT-biTPD to strongly suppress the dark current density (~10–10 A/cm2) at a negative bias (–2.0 V) while maintaining high responsivity (0.29 A/W) even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of Dsh*=2.18×1013 Jones in the OPDs. Printed OPDs are developed by slot-die coating for use in X-ray detectors, which exhibit Dsh* = 2.73×1012 Jones with clear rising (0.26 s) and falling (0.29 s) response times upon X-ray irradiation.

Poster